Blind Flange evidence report · EVAL-1 · recorded 2026-11-16T12:24:47Z · store revision 1 · plant: Gas processing plant (illustrative)
BLOCK PTW-2201 Restart compression on train Bassessment_status COMPLETE · conflict_verdict BLOCK · assessed at 2026-11-15T18:00:00Z (snapshot store) · search bound 100 hops
Findings (1) 1. BLOCK PRESSURE_REACHES_TEMPORARY_BARRIER (introduced) Pressure would reach BF-230, a temporary barrier that PTW-1230 relies on. It has not been pressure-tested.
Other permit: PTW-1230 Train C PSV-230 recertification
Path, 12 hops. Barriers holding beside the route are shown underneath; dashed boxes are unconfirmed.
Also reached from: K-220, V-100, V-120, WH-MAN
Possibly also from: L-EXP (only by an unconfirmed route or against declared flow).
Not listed as sources: C-400, MOL, P-310, P-41C (other services, no declared tie-in; pressure levels are not modelled).
Hazards before and after existing - introduced RELIES_ON BF-230 (PTW-1230) from C-400 RELIES_ON BF-230 (PTW-1230) from K-220 RELIES_ON BF-230 (PTW-1230) from L-EXP RELIES_ON BF-230 (PTW-1230) from MOL RELIES_ON BF-230 (PTW-1230) from P-310 RELIES_ON BF-230 (PTW-1230) from P-41C RELIES_ON BF-230 (PTW-1230) from V-100 RELIES_ON BF-230 (PTW-1230) from V-110 RELIES_ON BF-230 (PTW-1230) from V-120 RELIES_ON BF-230 (PTW-1230) from WH-MAN remaining - resolved -
Tag matching baseline No shared tags with any active permit: tag matching alone would pass this request.
Plant Red: the evidence paths (dark red: where they start). Blue: closed valves and installed blinds. Amber: unconfirmed state. Squares are valves and blinds.
BF-230: Blind flange fitted in place of PSV-230 (installed) BF-230 BV-211: Train A suction pressurisation bypass (small bore) (closed) BV-211 BV-221: Train B suction pressurisation bypass (small bore) (closed) BV-221 BV-231: Train C suction pressurisation bypass (small bore) (open) BV-231 BV-300: Dry gas filter bypass valve (open) BV-300 C-300: Glycol contactor (in_service) C-300 C-310: Glycol regenerator (in_service) C-310 C-400: Condensate stabiliser (in_service) C-400 DR-210: Train A scrubber drain valve (closed) DR-210 DR-220: Train B scrubber drain valve (closed) DR-220 DR-230: Train C scrubber drain valve (closed) DR-230 DR-300: Dry gas filter drain valve (closed) DR-300 DR-41A: Condensate pump A casing drain (closed) DR-41A DR-41B: Condensate pump B casing drain (closed) DR-41B DR-41C: Condensate pump C casing drain (closed) DR-41C DV-41A: Condensate pump A discharge valve (closed) DV-41A DV-41B: Condensate pump B discharge valve (closed) DV-41B DV-41C: Condensate pump C discharge valve (open) DV-41C E-210: Train A aftercooler (in_service) E-210 E-220: Train B aftercooler (in_service) E-220 E-230: Train C aftercooler (in_service) E-230 E-300: Gas/gas exchanger (in_service) E-300 F-300: Dry gas filter (shutdown) F-300 FQ-420: Condensate metering skid (in_service) FQ-420 FV-212: Train A anti-surge recycle valve (closed) FV-212 FV-222: Train B anti-surge recycle valve (open) FV-222 FV-232: Train C anti-surge recycle valve (closed) FV-232 FW-HDR: Fire water ring main (in_service) FW-HDR IA-HDR: Instrument air header (in_service) IA-HDR K-210: Train A gas compressor (shutdown) K-210 K-220: Train B gas compressor (in_service) K-220 K-230: Train C gas compressor (shutdown) K-230 L-100: Inlet flowline (in_service) L-100 L-101: Slug catcher gas outlet (in_service) L-101 L-110G: HP separator gas outlet (in_service) L-110G L-110L: HP separator liquid outlet (in_service) L-110L L-120G: LP separator gas outlet (in_service) L-120G L-120L: LP separator liquid outlet (in_service) L-120L L-210D: Train A compressor discharge (in_service) L-210D L-210R: Train A relief line (in_service) L-210R L-210S: Train A compressor suction (in_service) L-210S L-211: Train A suction line (in_service) L-211 L-213: Train A outlet to discharge header (in_service) L-213 L-220D: Train B compressor discharge (in_service) L-220D L-220R: Train B relief line (in_service) L-220R L-220S: Train B compressor suction (in_service) L-220S L-221: Train B suction line (in_service) L-221 L-223: Train B outlet to discharge header (in_service) L-223 L-230D: Train C compressor discharge (in_service) L-230D L-230R: Train C relief line (in_service) L-230R L-230S: Train C compressor suction (in_service) L-230S L-231: Train C suction line (in_service) L-231 L-233: Train C outlet to discharge header (in_service) L-233 L-300: Contactor gas outlet (in_service) L-300 L-301: Dry gas line (in_service) L-301 L-310: Rich glycol line (in_service) L-310 L-311: Lean glycol line (in_service) L-311 L-400: Stabiliser bottoms (in_service) L-400 L-41AD: Condensate pump A discharge line (in_service) L-41AD L-41AS: Condensate pump A suction line (in_service) L-41AS L-41BD: Condensate pump B discharge line (in_service) L-41BD L-41BS: Condensate pump B suction line (in_service) L-41BS L-41CD: Condensate pump C discharge line (in_service) L-41CD L-41CS: Condensate pump C suction line (in_service) L-41CS L-640: Stabiliser deluge line (in_service) L-640 L-CD: Condensate pump discharge header (in_service) L-CD L-CEX: Condensate export line (in_service) L-CEX L-CS: Condensate pump suction header (in_service) L-CS L-DISCH: Compressor discharge header (in_service) L-DISCH L-DRN: Closed drain header (in_service) L-DRN L-EXG: Export gas line (in_service) L-EXG L-EXP: Export gas pipeline (in_service) L-EXP L-FG: Fuel gas header (in_service) L-FG L-FLR: HP flare header (in_service) L-FLR L-FLS: Flare stack line (in_service) L-FLS L-IA: Instrument air distribution to valve actuators (in_service) L-IA L-MTR: Export gas metering run (in_service) L-MTR L-N2-610: Train C nitrogen purge spool (in_service) L-N2-610 L-SUCT: Compressor suction header (in_service) L-SUCT LV-110: HP separator level valve (open) LV-110 LV-310: Contactor glycol level valve (open) LV-310 MOL: Main oil line (in_service) MOL MV-41A: Condensate pump A minimum-flow valve (closed) MV-41A MV-41B: Condensate pump B minimum-flow valve (closed) MV-41B MV-41C: Condensate pump C minimum-flow valve (open) MV-41C N2-HDR: Nitrogen header (in_service) N2-HDR NRV-210: Train A discharge non-return valve (open) NRV-210 NRV-220: Train B discharge non-return valve (open) NRV-220 NRV-230: Train C discharge non-return valve (open) NRV-230 NRV-41A: Condensate pump A non-return valve (open) NRV-41A NRV-41B: Condensate pump B non-return valve (open) NRV-41B NRV-41C: Condensate pump C non-return valve (open) NRV-41C P-310: Lean glycol pump (in_service) P-310 P-41A: Condensate pump A (shutdown) P-41A P-41B: Condensate pump B (shutdown) P-41B P-41C: Condensate pump C (in_service) P-41C PCV-120: Fuel gas pressure control valve (open) PCV-120 PL-500: Export pig launcher (shutdown) PL-500 PSV-210: Train A discharge relief valve (closed) PSV-210 PSV-220: Train B discharge relief valve (closed) PSV-220 PSV-230: Train C discharge relief valve (removed) PSV-230 PSV-41A: Condensate pump A relief valve (closed) PSV-41A PSV-41B: Condensate pump B relief valve (closed) PSV-41B PSV-41C: Condensate pump C relief valve (closed) PSV-41C RV-210: Train A relief valve inlet block valve (open) RV-210 RV-220: Train B relief valve inlet block valve (open) RV-220 RV-230: Train C relief valve inlet block valve (open) RV-230 RV-41A: Condensate pump A relief block valve (open) RV-41A RV-41B: Condensate pump B relief block valve (open) RV-41B RV-41C: Condensate pump C relief block valve (open) RV-41C SDV-100: Inlet shutdown valve (open) SDV-100 SDV-110: Compressor suction shutdown valve (open) SDV-110 SV-41A: Condensate pump A suction valve (closed) SV-41A SV-41B: Condensate pump B suction valve (closed) SV-41B SV-41C: Condensate pump C suction valve (open) SV-41C V-100: Slug catcher (in_service) V-100 V-110: HP separator (in_service) V-110 V-120: LP separator (in_service) V-120 V-210: Train A suction scrubber (in_service) V-210 V-220: Train B suction scrubber (in_service) V-220 V-230: Train C suction scrubber (in_service) V-230 V-DRN: Closed drain drum (in_service) V-DRN V-FLR: Flare knock-out drum (in_service) V-FLR VNT-210: Train A discharge vent to flare (closed) VNT-210 VNT-220: Train B discharge vent to flare (closed) VNT-220 VNT-230: Train C discharge vent to flare (closed) VNT-230 VNT-500: Pig launcher vent valve (open) VNT-500 WH-MAN: Wellhead production manifold (in_service) WH-MAN XV-211: Train A suction isolation valve (closed) XV-211 XV-213: Train A discharge isolation valve (closed) XV-213 XV-215: Train A seal gas supply valve (open) XV-215 XV-221: Train B suction isolation valve (open) XV-221 XV-223: Train B discharge isolation valve (open) XV-223 XV-225: Train B seal gas supply valve (open) XV-225 XV-231: Train C suction isolation valve (closed) XV-231 XV-233: Train C discharge isolation valve (closed) XV-233 XV-235: Train C seal gas supply valve (closed) XV-235 XV-300: Glycol contactor inlet valve (open) XV-300 XV-301: Dry gas filter inlet valve (closed) XV-301 XV-302: Dry gas filter outlet valve (closed) XV-302 XV-400: Stabiliser feed valve (open) XV-400 XV-420: Condensate export valve (open) XV-420 XV-421: Main oil line tie-in valve (open) XV-421 XV-500: Export pipeline isolation valve (open) XV-500 XV-501: Pig launcher main valve (closed) XV-501 XV-502: Pig launcher kicker valve (closed) XV-502 XV-610: Train C nitrogen purge valve (closed) XV-610 XV-611: Train C nitrogen purge inlet valve (closed) XV-611 XV-620: Pig launcher nitrogen purge valve (closed) XV-620 XV-640: Fire water to stabiliser deluge (closed) XV-640 XV-TIE: Train B / train C discharge cross-tie valve (closed) XV-TIE
Decision support only. Not a safety system. The plant data is illustrative. Generated by blindflange report from the recorded evaluation; blindflange replay re-runs it from the same snapshot.